Mill test certificate
Issued to EN 10204 3.1, covering tensile strength, yield load, elongation and relaxation for the heat numbers supplied.
Every coil carries a test record keyed to its heat number. Nothing is packed until the tensile result is in, and nothing ships without a certificate your engineer can file.
Four properties decide whether a strand will behave as the design assumed over the life of the structure.
The minimum breaking load of the finished strand is verified against the grade. For 15.24 mm ASTM A416 Grade 270 strand this is 260 kN; for 12.7 mm it is 184 kN and for 9.53 mm it is 102.3 kN.
Elongation is reported to confirm ductility. A strand that reaches the specified load but fails with too little elongation is not a compliant strand, even though the breaking load looks correct.
Low-relaxation strand is stress-relieved so that the prestressing force does not bleed away under permanent load. The relaxation result is what separates a low-relaxation product from a normal-relaxation one.
Diameter, lay length, wire ovality and surface condition are checked before packing, because lay length and coating condition affect bond and fatigue behaviour in service.
A buyer or inspector should be able to match every delivered coil back to its test record.
Issued to EN 10204 3.1, covering tensile strength, yield load, elongation and relaxation for the heat numbers supplied.
Batch relaxation results reported against the low-relaxation requirement of the applicable standard, typically 2.5% or lower at 1000 hours.
Coil weights, tag numbers and packing details so the delivered material can be reconciled against the order and the test record.
SGS, BV or Intertek inspection certificates added when the purchase order or the approved vendor list requires them.
Open any preview to view the PDF. Each document applies only to the product and market stated on it — confirm coverage for your diameter, standard and destination before relying on it.
Management system
Quality management system certification.
Open PDF
European market
Conformity documentation for the European market.
Open PDF
Post-tensioning
Post-Tensioning Institute related certification.
Open PDF
Third-party
Independent product test report issued by SGS.
Open PDF
Tensile
Independent tensile test of strand by WJE.
Open PDF
Relaxation
Independent relaxation test of strand by WJE.
Open PDFInspection by SGS, BV or Intertek can be arranged before packing or before loading at Qingdao port, and the buyer may also nominate an inspector. The inspection stage and scope are written into the offer so the schedule does not slip because of an unplanned hold point.
For orders governed by an approved vendor list, state the required inspection stage, the standard to be verified, the document format and the witness points in the inquiry. If a project engineer needs to witness the tensile test, say so early — that has to be scheduled against the production batch, not added after packing.
A standard shipment carries a mill test certificate to EN 10204 3.1 covering tensile strength, yield load, elongation and relaxation for the supplied heat numbers, plus the coil packing list and tag numbers. Third-party inspection reports from SGS, BV or Intertek are added when the purchase order requires them.
Relaxation is verified per production batch and reported against the low-relaxation requirement of the applicable standard, typically 2.5% or lower at 1000 hours for ASTM A416 Grade 270 strand. The relaxation report is issued with the mill test certificate; confirm the test scope for your order on the purchase order.
Yes. Inspection by SGS, BV or Intertek can be arranged before packing or before loading at Qingdao port, and the buyer may nominate an inspector. State the inspection stage and scope in the inquiry so it can be priced into the offer and scheduled without delaying the shipment.
Each heat number is traced through drawing, stranding and stabilising, and the finished coil is tagged with its heat and batch reference. The mill test certificate links the reported tensile, elongation and relaxation results back to those references, so a buyer or inspector can match a delivered coil to its test record.
Send your standard, diameter and inspection requirement — our export engineers will confirm the document set and the schedule.